Atto-technology 2400C/R/D Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Atto-technology 2400C/R/D. ATTO Technology 2400C/R/D User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - ATTO FibreBridge

ATTO FibreBridgeInstallation and Operation ManualATTO FibreBridge 2370EEmbedded 4-Gigabit Fibre Channel to SCSI bridgeATTO FibreBridge 2390C/R/DMultip

Strany 2 - ATTO Technology, Inc

5ATTO Technology Inc. FibreBridge Installation and Operation Manual 1.2 ATTO FibreBridge 2390R/D Physical AttributesThe ATTO FibreBridge 2390R/D is a

Strany 3

6A bicolor Ready/Fault LED lights green to indicate ready, lights yellow to show a faulted condition, and is off to indicate not ready.Embedded in the

Strany 4 - Contents

7ATTO Technology Inc. FibreBridge Installation and Operation Manual 1.3 ATTO FibreBridge 2390C Physical AttributesThe ATTO FibreBridge 2390C is a 4-G

Strany 5

8no link is present. A separate blinking yellow LED indicates activity.A bicolor Ready/Fault LED lights green to indicate ready, lights yellow to show

Strany 6

9ATTO Technology Inc. FibreBridge Installation and Operation Manual 1.4 ATTO FibreBridge 2400R/D Physical AttributesThe ATTO FibreBridge 2400R/D is a

Strany 7

10LED indicatorsThe LED indicators can be viewed from the connector side and the front side of the FibreBridge 2400R/D. (See Exhibit 1.4-1)LEDs on the

Strany 8 - +12V GND GND +5V

11ATTO Technology Inc. FibreBridge Installation and Operation Manual 1.5 ATTO FibreBridge 2400C Physical AttributesThe ATTO FibreBridge 2400C is a hi

Strany 9

12Exhibit 1.5-1 FibreBridge 2400C bracket detail and board layoutReady/Fault LEDEthernet portFibre Channel portsSCSI portsSCSI activity LEDsFC activi

Strany 10 - CAUTIONCAUTION

13ATTO Technology Inc. FibreBridge Installation and Operation Manual 2.0 Install the FibreBridgeIf you have not already completed the instructions on

Strany 11

14 If you do not have a DHCP server, get an IP address and subnet mask from your network administrator, type it into the area provided, and click on

Strany 12 - 4 521 3 6

ATTO Technology, Inc.155 CrossPoint ParkwayAmherst, New York 14068 USAwww.attotech.comTel (716) 691-1999Fax (716) 691-9353 Sales support: sls@attotech

Strany 13

15ATTO Technology Inc. FibreBridge Installation and Operation Manual 3.0 Configure the FibreBridgeThe ExpressNAV interface provides information and m

Strany 14

16SCSI configurationEach SCSI port is configured separately. Displays include a list of attached devices for each bus. Configurable options are:• Port

Strany 15 - LED indicators

17ATTO Technology Inc. FibreBridge Installation and Operation Manual 3.1 Map DevicesAfter getting an IP address and entering ATTO ExpressNAV, you mus

Strany 16 - 6-pin connection pinouts

18Here, type in your user name and password, and click OK.1The Status page appears.2 From the ExpressNAV main menu, click on the Mapping menu item on

Strany 17 - 6.299 inches

19ATTO Technology Inc. FibreBridge Installation and Operation Manual 3.2 Monitor, Manage RemotelyThe Ethernet port provides monitoring and management

Strany 18 - 2.0 Install the FibreBridge

20SNMP-based monitoringThe Simple Network Management Protocol (SNMP) facilitates the exchange of management information between network devices. An ag

Strany 19 - Begin initial configuration

21ATTO Technology Inc. FibreBridge Installation and Operation ManualEmail messages provide error notificationEmail notification allows the FibreBridge

Strany 20 - Page descriptions

22Exhibit 3.0-5 The Email messages sent by the FibreBridge follow this format.Subject: [The Type of Event that Occurred] Message Body:This is a statu

Strany 21

23ATTO Technology Inc. FibreBridge Installation and Operation Manual 4.0 Modify System ValuesTo configure the ATTO FibreBridge, use ATTO ExpressNAV.

Strany 22 - 3.1 Map Devices

24SCSI device uses SpeedWrite performance enhancement by default.1 Follow the Preliminary steps. 2 From the left hand menu, click on Storage Managemen

Strany 24 - None: no messages are sent

25ATTO Technology Inc. FibreBridge Installation and Operation Manual 5.0 Update FirmwareThe ATTO FibreBridge has several processors which control the

Strany 26

27ATTO Technology Inc. FibreBridge Installation and Operation Manual 6.0 Interface optionsAlternative methods to the ATTO ExpressNAV interface may be

Strany 27 - Explanation

28• Flow Control: None• Terminal type: ASCII• Echo: on f. Click OK.4 After you connect to the FibreBridge, start-up messages are displayed. These mes

Strany 28 - 4.0 Modify System Values

i ATTO Technology Inc. FibreBridge Installation and Operation ManualAppendix A CablingATTO FibreBridge SCSI ports connect SCSI storage devices into

Strany 29 - Restart page and restart the

iiAppendix B CLI provides ASCII-based InterfaceThe command line interface (CLI) provides access to the ATTO FibreBridge Services through a set of AS

Strany 30 - 5.0 Update Firmware

iii ATTO Technology Inc. FibreBridge Installation and Operation ManualCLI error messagesThe following error messages may be returned by the Command li

Strany 31

ivExit exitFCConnMode loop set fcconnmode all ptpFCDataRate auto get fcdatarate 1FCHard disabled set fchard enabledFCHardAddress fp1=3fp2=4set fcharda

Strany 32 - 6.0 Interface options

v ATTO Technology Inc. FibreBridge Installation and Operation ManualSCSIPortBusSpeed ultra320 set scsiportbusspeed 2 ultra160SCSIPortList scsiportlist

Strany 33 - Using Telnet

viCommand explanationsAutoLogSenseControls whether current data from log pages in a SCSI target device is available automatically.Default: disabledset

Strany 34 - Appendix A Cabling

Contents 1.0 ATTO FibreBridge Provides Storage Options ...1ATTO FibreBridge 2370E features, benefitsATTO Fib

Strany 35

vii ATTO Technology Inc. FibreBridge Installation and Operation ManualDisplayEventLogFilterFilters the display of data for specified subsystems and le

Strany 36 - CLI summary reference

viiiEventLogRegulates event logging. When enabled, records various system events to the event log. Default: enabledset EventLog [enabled | disabled]ge

Strany 37 - Command Default Example

ix ATTO Technology Inc. FibreBridge Installation and Operation ManualFCSpeedLED2G (FB 2370)Configures the FC speed LED. When enabled, the LED lights f

Strany 38

xMaxOpTemp (FB 2390, FB 2400)Regulates/displays the maximum enclosure temperature alarm of the FibreBridge in degrees Celsius. If the temperature of t

Strany 39 - FCMultiNode (FB 2400)

xi ATTO Technology Inc. FibreBridge Installation and Operation ManualRestoreConfigurationRestores configuration to either the default configuration or

Strany 40

xiiSCSIPortWideTransferSpecifies whether wide SCSI transfers should be negotiated. Enabled allows wide transfer negotiation.Default: enabledset SCSIPo

Strany 41

xiii ATTO Technology Inc. FibreBridge Installation and Operation ManualSNTPServerControls/displays the main IP address of the SNTP time server. If the

Strany 42

xivVirtualRobotResponse Provides proxy responses to SCSI INQUIRY commands if an existing SCSI command is outstanding to a Media Changer. All other SCS

Strany 43

xv ATTO Technology Inc. FibreBridge Installation and Operation ManualAppendix C Standards and CompliancesThe equipment described in this manual gene

Strany 44 - LogicalUnitAddressing

xviCertification for the FibreBridge 2400 onlyUL60950-1/CSA C22.2 No. 60950-1

Strany 45

2.0 Install the FibreBridge ...13Unpack the packing box; verify cont

Strany 46

xvii ATTO Technology Inc. FibreBridge Installation and Operation ManualAppendix D Warranty InformationManufacturer limited warrantyManufacturer warr

Strany 47

1ATTO Technology Inc. FibreBridge Installation and Operation Manual 1.0 ATTO FibreBridge Provides Storage OptionsThe ATTO FibreBridge™ family of prod

Strany 48 - European Standards

2• SFP FC connector• Support for direct connect to F-port fabric switches, full duplex FC data transfers and FC-AL, PLDA and public look login• Two

Strany 49

3ATTO Technology Inc. FibreBridge Installation and Operation Manual 1.1 ATTO FibreBridge 2370E Physical AttributesThe ATTO FibreBridge 2370E is a 4-G

Strany 50 - Manufacturer limited warranty

4Exhibit 1.1-1 FibreBridge 2370E board layout

Příbuzné modely 2370E | 2390C/R/D |

Komentáře k této Příručce

Žádné komentáře